Everlux AL


"As recent accidents, notably the fire in the Gotthard tunnel in June 2001, show that self-rescuing offers the highest potential for saving lives in the case of an accident in a tunnel, the introduction of clear and self explanatory signs in sufficient numbers indicating the safety equipment in each tunnel is an important measure that can be implemented at relatively low cost.” 

To prevent accidents in tunnels and their repercussions, the European Parliament and Council have approved the European Directive 2004/54/EC of 29th of April which defines the minimum safety requirements for tunnels in the Trans-European Road Network.

In enclosed environments like road and rail tunnels, accidents often result in tragic consequences, particularly if the incident is fire related. This risk may be increased significantly if there is a lack of consistent, continuous safety information giving details of escape routes, fire safety equipment, emergency phones, safe areas etc. In the event of an incident or accident, the first ten to fifteen minutes are crucial when it comes to people’s safety and damage limitation. photoluminescent safety signs for tunnels provide an effective means of reducing risks by communicating clear, unambiguous instructions and by providing guidance. photoluminescent safety signs for tunnels are manufactured on an aluminium base which guarantees high performance in extreme conditions.



Technical Characteristics

Everlux-AL signs are supplied fitted with a damage resistant transparent protective film which offers protection against acts of vandalism and environmental conditions such as humidity and moisture.

Minimum luminance properties tested in accordance with Annex A of BS ISO 16069:
Luminance properties: Considering the stimulation of a 1000Lux – 6500K light for 5 minutes

Standard
Luminance Intensity (mcd/m2) 
(after removing the exciting light)
Period of Light Decay
10 minutes60 minutesLuminance Intensity greater than a 0.3 mcd/m2
BS ISO 16 069140 mcd/m220 mcd/m21800 minutes

150 mcd/m221 mcd/m22000 minutes
The luminance intensity of the non-slip self-adhesive strips on the floor may be lower due to the protective layer of polycarbonate.
 
Minimum luminance required in installed position in accordance with BS ISO 16069:
Luminance properties: Considering the stimulation of a 25 Lux - 4000K light for 15 minutes

Standard
Luminance Intensity (mcd/m2)
(after removing the exciting light)
Period of Light Decay
10 minutes60 minutes90 minutes
BS ISO 16 06930 mcd/m27 mcd/m25 mcd/m2
80 mcd/m210 mcd/m25.5 mcd/m2


Material: Durable 2mm thick aluminium, photoluminescent (phosphorescent); 
Printing: Serigraphy, high-quality gloss paint with UV resistance; 
Fire Resistance: Non-flammable; 
Chemical Characteristics: Non-radioactive, non-phosphorous, lead-free and non-toxic; 
Guarantee: In normal conditions of mounting and adequate cleaning, we offer a 5-year guarantee.